Overview
The HDU-100 is a data acquisition and control unit designed for tank level measurement, draft correction, and volume calculation in marine and industrial applications. It features RS-485 and RS-232 communication with MODBUS RTU support, allowing seamless integration with cargo monitoring and alarm systems.
1. Safety Information (p.3-4)
- Electrical Hazards:
- Power must be isolated before installation or maintenance.
- Equipment operates at high voltage, requiring extreme caution.
- Electrostatic Discharge (ESD) Precautions:
- Handle PCBs with care to prevent static damage.
- Use conductive packaging for PCB storage.
- DO NOT remove or replace PCBs while power is applied.
2. Storage Before Installation (p.5)
- Store in a dry, covered area to protect from moisture and extreme temperatures.
- Inspect components for physical damage before installation.
3. Features & System Description (p.6-7)
- Tank Level Monitoring: Acquires corrected level and volume data based on draft correction and inclinometer readings.
- Multi-Channel Input & Output:
- Communicates with AD-80, AD-82, HPI-100, and DA-80 via RS-485 MODBUS RTU.
- Supports 4-20mA current output for tank level and volume data.
- Alarm System:
- Dry contact relay output for system fault or communication failure alarms.
- Buzzer and LED indicators for real-time alerts.
- Draft Correction & Trim Calculation:
- Uses inclinometer and sensor readings to calculate trim and list correction factors.
4. Technical Specifications (p.6-7)
- Power Supply: 24V DC (0.5A, 10W power consumption)
- Communication Interfaces:
- 1 x RS-232 port
- 3 x RS-485 MODBUS RTU ports
- Environmental Conditions:
- Operating Temperature: -5°C to +55°C
- Storage Temperature: -20°C to +70°C
- Humidity Range: 10-90% (Operating), 5-95% (Storage)
- Mechanical Data:
- Dimensions: 132 × 315 × 30 mm (H × W × D)
- Weight: 800g
- Panel Flush Mounting
5. Installation & Wiring (p.7-8)
- Power Supply: 24V DC (18~32V range) with galvanic isolation.
- Communication Wiring:
- RS-485 for Master-Slave MODBUS RTU communication.
- RS-232 for external system connections.
- Tank Level Sensor Connection:
- Configured for cargo tank level input and volume calculation.
6. Communication & MODBUS Protocol (p.8-10)
- MODBUS RTU Communication Settings:
- Baud Rate: 9600bps
- Data Bits: 8
- Stop Bits: 1
- Parity: None
- MODBUS Data Register Map:
- Tank Level Data (0x1200 – 0x15FE)
- Tank Volume Data (0x1600 – 0x17FE)
- Draft & Inclinometer Values (0x1800 – 0x181E)
- Gravity Correction Factors (0x1814 – 0x181C)
- MODBUS Example Read Command:
- Retrieves salinity, temperature, or tank level data.
7. Draft & Volume Calculation Functions (p.11-12)
- Draft Calculation Formula:
- Computes trim correction and list correction based on inclinometer readings.
- Corrected Level Calculation:
- Applies draft correction for accurate tank volume measurement.
- Volume Calculation:
- Uses predefined volume table to determine cargo volume.
8. Operation & System Functions (p.12-16)
- LCD Display & Brightness Control:
- Adjust brightness via F2 (increase) and F5 (decrease) keys.
- Channel Display Navigation:
- Use F1 and F6 keys to switch between input channels.
- Manual Input Functions:
- Manual Draft Input: Allows input of trim and list values.
- Specific Gravity Input: Adjusts sea water, H.F.O., fresh water gravity settings.
- System Settings:
- Tank Configuration: Set total tank numbers and input types.
- Communication Addressing: Configure RS-485 slave address.
- Clock Settings: Adjust date and time.
- Password Protection: Restricts access to system settings.
9. Alarm System (p.17-18)
- System Alarms:
- Activated if sensor input exceeds normal range.
- Displayed via buzzer and LED indicators.
- Communication Alarms:
- Triggered by RS-232 or RS-485 port failures.
- Dry Contact Output:
- Used for external alarm relay activation.
10. Revision History (p.19)
- Version R3 (2025.03.03) – Third revision of the technical manual.