Overview
The Manifold Pressure Monitoring System (MPMS) is designed for real-time pressure monitoring of manifold lines in industrial applications. The system provides alarm notifications, data logging, and remote communication via RS-485. It consists of pressure transmitters, an embedded PC, A/D converters, intrinsically safe barriers, and a printer.
1. Safety Information (p.4-5)
- Electrical Hazard: Disconnect power before maintenance.
- Anti-Static Precautions: Handle PCBs with proper grounding to avoid static damage.
- Storage Conditions: Keep equipment dry and away from extreme temperatures.
2. System Components (p.8-13)
2.1 Embedded PC
- CPU: 32-bit ARM Cortex-A8, 1GHz
- Memory: 256MB SDRAM, 256MB NAND Flash
- Display: 10.2” TFT LCD, Touchscreen
- Communication: RS-232/RS-485, Ethernet
2.2 A/D Converter (DL-1100)
- Input: 8-channel, 4-20mA
- Communication: RS-485 (Modbus)
2.3 Pressure Transmitter (PL40 Series)
- Measurement Range: -1 bar to 50 bar
- Accuracy: ±0.20% FS
- Output: 4-20mA DC, 2-wire
- Protection: IP67, -40°C to +85°C operating temperature
2.4 Intrinsically Safe Barrier (KFD0-CS-Ex2.51P)
- Prevents electrical hazards in explosive areas.
- Input: 0-20mA, 2 channels
2.5 Printer
- Print Method: Direct Thermal
- Baud Rate: 2400-115200bps
- Interface: RS-232, Parallel
3. System Operation (p.14-19)
3.1 MPMS Software Functions
- Real-time pressure monitoring with trend curves.
- Alarm notifications for pressure exceedances.
- Historical data logging and report printing.
3.2 Display Modes
- Table View: Displays real-time pressure values and alarms.
- Trend Curve: Graphical pressure variation over time.
3.3 Alarm System
- Red Text: Alarm activated.
- Audible Buzzer: Can be enabled/disabled.
- Log Storage: 3-month retention for historical data.
4. System Configuration (p.20-33)
4.1 Password Management
- Operator Level: Basic settings.
- Master Level: Password change and security settings.
4.2 Communication Settings
- RS-485 Modbus communication for integration with other monitoring systems.
4.3 Environmental Settings
- Pressure Units: Configurable to bar, psi, or kPa.
- Alarm Sound: Enable/disable function.
5. Troubleshooting Guide (p.34-38)
Issue | Cause | Solution |
---|---|---|
No power indication | Faulty fuse or wiring | Replace fuse, check wiring |
No alarm activation | Sensor wiring issue | Check wiring & perform self-test |
False alarms | Electrical interference | Check grounding and shielding |
No data recording | Database full | Delete old logs and restart |
6. Storage & Maintenance (p.6)
- Keep dry and avoid moisture exposure.
- Inspect cables and connectors periodically.
- Backup log files every three months.
Related Documents (p.39)
- DL-1100 Operating Manual
- PL40-U Pressure Transmitter Manual
- KFD0-CS-Ex2.51P Intrinsically Safe Barrier Manual