Overview
The Fixed Gas Sampling System (FGSS - GSS-200) is designed for continuous monitoring of hazardous gas concentrations in shipboard environments. This system features dual pumps for redundancy, real-time gas detection, and automatic safety shutdown mechanisms to prevent gas accumulation.
1. Safety Information (p.6-8)
- Electrical Hazard: Ensure power isolation before installation or maintenance.
- Anti-Static Precautions: Handle PCBs with proper grounding.
- Storage Conditions: Store in dry areas, away from moisture and extreme temperatures.
2. System Components (p.12-16)
2.1 Analyzing Unit (PCB)
- Converts gas concentration readings into digital signals.
- Provides RS-485 communication with display and external monitoring systems.
- Alarm Relays: Supports 2-level gas alarms (pre-alarm and main alarm).
2.2 Display Unit (Control Unit)
- 12.1-inch touchscreen LCD for real-time system monitoring.
- Displays gas concentration levels, alarm status, and diagnostic messages.
2.3 Gas Detectors
- Detects CH4, O2, CO2, H2S, and other gases.
- Signal Output: 4-20mA.
- Response Time: <30 seconds.
2.4 Solenoid Valves
- DC 24V 2-way and 3-way valves for gas sampling.
- Controls gas flow to sampling channels.
2.5 Flow Meter
- Measures airflow rate in the sampling line.
3. System Operation (p.17-24)
3.1 Startup Procedure
- Verify all gas sampling channels are open.
- Power on the display unit (HGS-200CS).
- System enters initialization mode for sensor stabilization (120 sec).
- Begins sampling sequence and displays gas concentration levels.
3.2 Alarm & Fault Indications
Alarm Type |
Cause |
Display Color |
Pre-Alarm |
Gas approaching threshold |
Yellow |
Main Alarm |
Gas exceeds threshold |
Red |
Detector Fault |
Sensor malfunction |
Magenta |
Flow Fault |
Airflow abnormality |
Blue |
Communication Fault |
Data transmission error |
Magenta |
4. Configuration & Calibration (p.27-42)
4.1 System Settings
- Alarm thresholds, sensor configurations, and sampling time intervals.
- Password protection for critical settings.
4.2 Gas Detector Calibration
- Zero Calibration: Adjusts baseline at 4mA signal.
- Span Calibration: Sets 100% scale at 20mA using calibration gas.
4.3 Flow Calibration (Pressure Transmitter)
- Adjusts airflow measurements to ensure accuracy.
- Verifies pressure transmitter output for correct sampling flow.
5. Troubleshooting & Maintenance (p.53-56)
Issue |
Possible Cause |
Solution |
No Power |
Circuit breaker tripped |
Reset or replace breaker |
No Display |
Power supply failure |
Check and replace unit |
Gas Alarm Triggered |
High gas concentration |
Ventilate area and check for leaks |
Flow Fault |
Blocked sampling line |
Inspect valves and tubing |
Communication Error |
Wiring issue |
Verify RS-485 connections |
6. Storage & Handling (p.8)
- Store components in dry, static-free environments.
- Ensure gas detectors are properly sealed before installation.
- Inspect all parts before deployment.
7. Related Documents (p.65)
- Honeywell Sensepoint XCD Gas Detector Manual
- Teledyne GD10P Gas Detector Manual
- HANLA IMS GDS-200 Manual